Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
7.500 inches nominal
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Shielding Method
internal shield brought out to terminal
-
Body Length
6.630 inches minimum and 6.750 inches maximum
-
Body Width
6.380 inches minimum and 6.500 inches maximum
-
Mounting Method
flange and unthreaded hole
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
5.750 inches nominal
-
Mounting Hole Diameter
0.281 inches nominal
-
Body Height
7.500 inches minimum and 7.750 inches maximum
-
Maximum Operating Temp
105.0 deg celsius
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
1 primary and 1 secondary
-
Winding Tap Location
multiple taps w/o center tap
-
Winding Operating Current
10.0 amperes ac maximum
-
Winding Operating Voltage
110.00 ac volts nominal and 120.00 ac volts nominal and 125.00 ac volts nominal
-
Winding Operating Voltage
120.00 ac volts nominal
-
Unpackaged Unit Weight
30.000 pounds
-
Terminal Type And Quantity
2 solder stud and 5 tab,solder lug