HQNPA3060

Circuit Breakers

CIRCUIT BREAKER

HQNPA3060

5925-00-167-7500

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 screw

  • Body Length

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.737 inches nominal

  • Boss Height

    0.187 inches nominal

  • Pole Quantity

    3

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    any acceptable

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Body Style

    11b multipole-single actuator type

  • Body Width

    3.000 inches nominal

  • Body Height

    2.275 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    2.875 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...