FL10346
Filters and Networks
FILTER,BAND PASS
FL10346
Telephone Systems/Communications
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Load Impedance Per Function
600.0 ohms 2nd band pass
-
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
-
Body Width
1.500 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Frequency Band Width Per Function
600.00 hertz 2nd band pass and 2.40 kilohertz 2nd band pass
-
Reference Frequency Per Function
1.0 single radio interference pulses per second
-
Inclosure Type
encased
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Mounting Facility Type And Quantity
1 terminal
-
Body Length
2.000 inches nominal
-
Voltage Standing Wave Ratio Frequency Limits Per Function
600.0 single high pass pulses per second and 2.4 single radio interference pulses per second
-
Specified Frequencies Of Discrimination Per Function
15.00 hertz 2nd band pass and 2.40 kilohertz 2nd band pass and 600.00 hertz 2nd band pass and 3.78 kilohertz 2nd band pass
-
Overall Height
5.906 inches nominal
-
Body Material
metal
-
Reference Frequency Per Function
1.0 single radio interference two phase to two phase
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Specified Frequencies Of Discrimination Per Function
600.00 hertz 1st band pass and 15.00 hertz 1st band pass and 2.40 kilohertz 1st band pass and 3.78 kilohertz 1st band pass
-
Functional Terminal Type And Quantity
1 connector, plug output 2nd function
-
Voltage Standing Wave Ratio Frequency Limits Per Function
600.0 single high pass two phase to two phase and 2.4 single radio interference two phase to two phase
-
Load Impedance Per Function
600.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
1 connector, plug input 1st function
-
Source Impedance Rating Per Function
600.0 ohms 1st band pass
-
Frequency Band Width Per Function
600.00 hertz 1st band pass and 2.40 kilohertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
End Item Identification
communication system c07244/tsc-54
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Average Life Rating In Hours
750000.0
-
Body Height
3.750 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 30.0 maximum 1st band pass