Technical Characteristics

  • Thread Class

    2a

  • Overall Length

    3.500 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    1.600 inches nominal

  • Frequency Rating

    400.0 hertz nominal

  • Input-Output Phase Relationship

    single phase to single phase

  • Maximum Transformer Power Rating

    179.5 volt-ampere

  • Body Length

    3.000 inches maximum

  • Body Height

    3.400 inches maximum

  • Maximum Operating Temp

    105.0 deg celsius

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Quantity

    4

  • Mounting Method

    threaded stud

  • Winding Tap Location

    multiple taps w/o center tap

  • Winding Operating Current

    100.0 milliamperes ac nominal

  • Winding Operating Current

    5.0 amperes ac nominal

  • Winding Operating Voltage

    43.00 ac volts nominal

  • Cognizant Service

    usaf

  • Thread Direction

    right-hand

  • Reliability Indicator

    not established

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    2.100 inches nominal

  • Overall Height

    4.025 inches nominal

  • Winding Shielding Method

    core grounded and internal shield brought out to terminal

  • Body Width

    2.500 inches maximum

  • Winding Function And Quantity

    1 primary and 5 secondary

  • Nominal Thread Size

    0.190 inches

  • Winding Operating Current

    1.0 amperes ac nominal

  • Winding Power Rating

    29.0 volts-amperes

  • Winding Power Rating

    4.3 volts-amperes

  • Winding Power Rating

    80.0 volts-amperes

  • Winding Operating Voltage

    107.00 ac volts nominal and 115.00 ac volts nominal and 120.00 ac volts nominal

  • Winding Operating Voltage

    16.00 ac volts nominal

  • Winding Operating Voltage

    29.00 ac volts nominal

  • Special Features

    one primary winding;five secondary windings and item has two internal shields

  • Thread Series Designator

    unf

  • Terminal Type And Quantity

    16 solder stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...