GB3-A3-0.5-1

Circuit Breakers

CIRCUIT BREAKER

GB3-A3-0.5-1

5925-00-170-4081

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and fungus resistant and vibration resistant

  • Body Width

    4.490 inches minimum and 4.510 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.583 inches minimum and 4.603 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    0.5 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.490 inches minimum and 1.510 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Boss Height

    0.177 inches minimum and 0.197 inches maximum

  • Body Length

    5.990 inches minimum and 6.010 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    4.000 pounds

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    4.427 inches minimum and 4.447 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct all locations and 250.000 maximum at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Unthreaded Mounting Hole Diameter

    0.256 inches minimum and 0.276 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    5.115 inches minimum and 5.135 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.490 inches minimum and 1.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...