72-330-1MG6

Circuit Breakers

CIRCUIT BREAKER

72-330-1MG6

5925-00-173-1036

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Ultimate Trip Time Per Pole In Seconds

    500.000 nominal all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Switch Current Rating And Type In Amps

    20.0 ac

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    1.950 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.070 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Body Length

    2.530 inches nominal

  • Body Width

    2.280 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Switch Terminal Type

    threaded stud

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Mounting Surface To Terminal End Distance

    2.540 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Actuator Function

    reset

  • Trip Release Characteristic

    time delay all locations

  • Boss Height

    0.150 inches nominal

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...