MIL-C-5809
Circuit Breakers
CIRCUIT BREAKER
MIL-C-5809
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.189 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
55.000 maximum at 200 pct single location and 2.000 minimum at 400 pct single location and 15.000 minimum at 200 pct single location and 7.000 maximum at 400 pct single location
-
Body Width
0.750 inches maximum
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Bushing Length
0.250 inches nominal
-
Thread Series Designator
unc
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Internal Trip Release Configuration
series trip single location
-
Body Length
2.189 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
-
Case Material
metal
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
explosion resistant and hermetically sealed and moisture resistant
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Release Method
thermal single location
-
Center To Center Distance Between Terminals Parallel To Length
1.188 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
2 threaded hole
-
Terminal Type And Quantity
2 screw
-
Specification/Standard Data
96906-ms25017 government standard
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
~1
data on certain environmental and performance