MCA2

Circuit Breakers

CIRCUIT BREAKER

MCA2

5925-00-173-7650

5925 - Circuit Breakers

Met-Pro Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.234 inches nominal

  • Unpackaged Unit Weight

    1.000 ounces

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 ac single location and 875.0 dc single location

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.574 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location and 30.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Body Width

    1.343 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Overall Length

    2.000 inches nominal

  • Reset Method

    automatic

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...