FD3025V

Circuit Breakers

CIRCUIT BREAKER

FD3025V

5925-00-174-6327

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    16.000 minimum at 200 pct all locations and 45.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.000 inches nominal

  • Body Width

    4.150 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Boss Height

    0.120 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.350 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.445 inches nominal

  • Body Height

    3.370 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.350 inches nominal

  • Body Length

    5.950 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Ultimate Trip Time Per Pole In Seconds

    90.000 minimum all locations and 3600.000 maximum all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...