612457-26

Circuit Breakers

CIRCUIT BREAKER

612457-26

5925-00-175-2655

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.765 inches nominal

  • Reset Method

    automatic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    60.0 ac single location and 60.0 dc single location

  • Case Material

    plastic

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    general purpose

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 ac single location and 30.0 dc single location

  • Nominal Thread Size

    0.164 inches

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    1.850 ounces

  • Mounting Surface To Terminal End Distance

    1.499 inches nominal

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.437 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Terminal Type And Quantity

    2 screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    122.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    21.500 nominal at 300 pct single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Body Length

    2.203 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Thread Series Designator

    unc

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...