P320A60

Resistors

RESISTOR,THERMAL

P320A60

5905-00-175-5447

5905 - Resistors

Itt Corporation

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Zero Power Resistance At Specified Temp

    3.045 kilohms 3rd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    25.0 deg celsius 5th resistance-temperature point

  • Terminal Length

    3.750 inches minimum

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -9.0/+9.0 2nd resistance-temperature point

  • Power Dissipation Constant In Milliwatts Per Deg Celsius

    150.0

  • Cubic Measure

    0.342 cubic inches

  • Thermal Time Constant In Seconds

    80.0

  • Temp Points For Resistance Readings At Zero Power

    -10.0 deg celsius 3rd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    58.0 ohms 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    116.0 ohms 7th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    75.0 deg celsius 7th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -11.0/+11.0 1st resistance-temperature point

  • Distance Between Mounting Facility Centers

    1.000 inches nominal

  • Zero Power Resistance At Specified Temp

    2.465 kilohms 4th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -7.0/+7.0 4th resistance-temperature point

  • Reference Temp In Deg Celsius

    25.0

  • Resistance Tolerance At A Specified Temp In Percent

    -5.0/+5.0 5th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -7.0/+7.0 6th resistance-temperature point

  • Terminal Diameter

    0.025 inches nominal

  • Style Designator

    disk on surface plate

  • Zero Power Resistance At Specified Temp

    25.375 ohms 9th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    0.0 deg celsius 4th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    725.0 ohms 5th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -8.4/+8.4 3rd resistance-temperature point

  • Ambient Temp At Full Rated Power

    25.0 deg celsius

  • Zero Power Resistance At Specified Temp

    46.4 kilohms 1st resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -30.0 deg celsius 2nd resistance-temperature point

  • Reliability Indicator

    not established

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.0624 inches nominal

  • Overall Length

    1.250 inches nominal

  • Inclosure Type

    encapsulated

  • Zero Power Resistance At Specified Temp

    239.25 ohms 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -8.6/+8.6 7th resistance-temperature point

  • Unthreaded Mounting Hole Diameter

    0.1285 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -8.9/+8.9 8th resistance-temperature point

  • Zero Power Resistance

    725.000 ohms

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.6874 inches nominal

  • Zero Power Resistance At Specified Temp

    13.05 ohms 10th resistance-temperature point

  • Terminal Surface Treatment

    solder

  • Resistance Tolerance At A Specified Temp In Percent

    -12.1/+12.1 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -50.0 deg celsius 1st resistance-temperature point

  • Maximum Operating Temp

    150.0 deg celsius

  • Temp Points For Resistance Readings At Zero Power

    125.0 deg celsius 9th resistance-temperature point

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -5.0/+5.0

  • Resistance Tolerance At A Specified Temp In Percent

    -10.0/+10.0 9th resistance-temperature point

  • Overall Height

    0.313 inches nominal

  • Terminal Type And Quantity

    1 wire lead

  • Overall Width

    0.875 inches nominal

  • Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius

    4.40

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    100.0 deg celsius 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    13.05 kilohms 2nd resistance-temperature point

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...