G80FC24A4C1D
Switches
SWITCH,ROTARY
G80FC24A4C1D
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Hazardous Locations/Environmental Protection
explosion proof
-
Mounting Method
threaded bushing single mounting facility
-
Thread Quantity Per Inch
32 single mounting facility
-
Thread Class
2a single mounting facility
-
Contact Load Current Rating
5.0 amperes resistive load ac at sea level and 2.0 amperes inductive load ac at sea level
-
Contact Load Current Rating
3.0 amperes resistive load dc at sea level and 1.0 amperes inductive load dc at sea level
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-s-3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Switch Actuator Indexing Position Quantity
24 single actuator
-
Contact Voltage Rating In Volts
115.0 ac at sea level
-
Contact Switching Action
breaks before makes each section rear
-
Switch Actuator Positioning Increment
15.0 degrees single actuator
-
Err Default
err default and err default
-
Individual Section Quantity
4
-
Style Designator
tap, circular, bushing mount
-
Shaft Type
round, flatted single actuator
-
Flat Height
0.208 inches minimum single actuator and 0.212 inches maximum single actuator
-
Thread Series Designator
uns single mounting facility
-
Throw Quantity
24 each section rear
-
Terminal Type
tab, solder lug
-
Operating Temp Range
-65.0/+125.0 deg celsius
-
Shaft Length
0.720 inches minimum single actuator and 0.840 inches maximum single actuator
-
Overall Length
3.035 inches maximum
-
Nominal Thread Size
0.469 inches single mounting facility
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Rotor Through Connection Quantity
1 each section
-
Shaft Diameter
0.248 inches minimum single actuator and 0.252 inches maximum single actuator
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Nonturn Device Type
slotted bushing at 12:00 o'clock
-
First Flat Length
0.240 inches minimum single actuator and 0.260 inches maximum single actuator
-
Overall Diameter
2.000 inches maximum
-
Shaft Flat/Slot Angular Location
0.0 degrees from contact position 1 single actuator
-
Pole Quantity
1 each section front
-
Switch Actuator Stop Device Type
fixed stop single actuator