68C40029-7-5

Circuit Breakers

CIRCUIT BREAKER

68C40029-7-5

5925-00-179-8267

5925 - Circuit Breakers

Air Force Logistics Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Nominal Thread Size

    0.469 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 16.000 maximum at 200 pct single location

  • Test Data Document

    97151-68c40029 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 6000.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Unpackaged Unit Weight

    1.000 ounces

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.240 inches minimum and 0.260 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.696 inches minimum and 0.716 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.208 inches minimum and 1.228 inches maximum

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location and 7.5 amperes dc single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...