APL111-19-282R
Circuit Breakers
CIRCUIT BREAKER
APL111-19-282R
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Boss Height
0.125 inches minimum and 0.155 inches maximum
-
Mounting Surface To Terminal End Distance
2.650 inches minimum and 2.800 inches maximum
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 2000.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one,two,and three linked
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
internal at each pole
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 10.000 maximum at 200 pct
-
Unpackaged Unit Weight
0.875 pounds
-
Test Data Document
05869-711570 drawing
-
Body Length
2.485 inches minimum and 2.515 inches maximum
-
Body Width
2.230 inches minimum and 2.270 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Thread Series Designator
unc
-
Body Style
multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.047 inches minimum and 2.077 inches maximum
-
Switch Contact Arrangement
single pole,double throw
-
Fragility Factor
moderately rugged
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc
-
Trip Release Method
magnetic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Auxiliary Switch Function And Quantity
1 alarm
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant and moisture resistant
-
Switch Terminal Type
tab,solder lug
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc
-
Frequency In Hertz
60.0
-
Terminal Type And Quantity
6 threaded stud