Technical Characteristics

  • Nonturn Device Radius

    0.432 inches nominal at 3:00 o'clock

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    breaks before makes each section rear

  • Err Default

    err default and err default

  • Individual Section Quantity

    4

  • First Flat Length

    0.250 inches nominal single actuator

  • Flat Height

    0.209 inches minimum single actuator and 0.219 inches maximum single actuator

  • Contact Load Current Rating

    1.0 amperes resistive load ac at sea level

  • Style Designator

    tap, circular, bushing mount

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Shaft Type

    round, flatted single actuator

  • Contact Load Current Rating

    500.0 milliamperes resistive load dc at sea level and 250.0 milliamperes inductive load dc at sea level

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Mounting Method

    threaded bushing single mounting facility

  • Pole Quantity

    2 each section rear

  • Switch Actuator Indexing Position Quantity

    4 single actuator

  • Thread Class

    2a single mounting facility

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Throw Quantity

    4 each section rear

  • Terminal Type

    tab, solder lug

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.251 inches maximum single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Shaft Flat/Slot Angular Location

    0.0 degrees from contact position 1 single actuator

  • Shaft Length

    0.834 inches minimum single actuator and 0.914 inches maximum single actuator

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Overall Length

    2.959 inches minimum and 3.039 inches maximum

  • Overall Diameter

    1.100 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...