990C184H01

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

990C184H01

5915-00-189-4015

5915 - Filters and Networks

Northrop Grumman Systems Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 3rd radio interference 3rd function

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 4th radio interference 4th function

  • Mounting Facility Screw Thread Series Designator

    unf

  • Functional Terminal Type And Quantity

    8 threaded stud output 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Overall Length

    9.375 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Current Rating Per Function In Amps

    25.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    25.0 6th radio interference

  • Body Width

    4.938 inches minimum and 5.062 inches maximum

  • Functional Terminal Type And Quantity

    1 threaded stud ground 3rd function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 1st radio interference 1st function

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 2nd radio interference 2nd function

  • Body Height

    5.938 inches minimum and 6.062 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    30.0 2nd radio interference

  • Mounting Facility Type And Quantity

    1 threaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Overall Height

    6.080 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Nominal Thread Size

    0.190 inches

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Operating Current Rating Per Function In Amps

    30.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.735 inches minimum and 7.765 inches maximum

  • Operating Current Rating Per Function In Amps

    30.0 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Body Surface Treatment

    tin

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    3 connector, receptacle input 1st function

  • Special Features

    eight filtered functions

  • Operating Current Rating Per Function In Amps

    30.0 1st radio interference

  • Body Length

    8.563 inches minimum and 8.687 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 5th radio interference 5th function

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    4.235 inches minimum and 4.265 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Features Provided

    nut and washer

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...