990C184H01
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
990C184H01
Northrop Grumman Systems Corporation
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 4th radio interference 4th function
-
Mounting Facility Screw Thread Series Designator
unf
-
Functional Terminal Type And Quantity
8 threaded stud output 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Overall Length
9.375 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
25.0 5th radio interference
-
Operating Current Rating Per Function In Amps
25.0 6th radio interference
-
Body Width
4.938 inches minimum and 5.062 inches maximum
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 1st radio interference 1st function
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 2nd radio interference 2nd function
-
Body Height
5.938 inches minimum and 6.062 inches maximum
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Current Rating Per Function In Amps
30.0 2nd radio interference
-
Mounting Facility Type And Quantity
1 threaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Overall Height
6.080 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Nominal Thread Size
0.190 inches
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference 6th function
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Current Rating Per Function In Amps
30.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.735 inches minimum and 7.765 inches maximum
-
Operating Current Rating Per Function In Amps
30.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
-
Body Surface Treatment
tin
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
3 connector, receptacle input 1st function
-
Special Features
eight filtered functions
-
Operating Current Rating Per Function In Amps
30.0 1st radio interference
-
Body Length
8.563 inches minimum and 8.687 inches maximum
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Inclosure Type
hermetically sealed
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.235 inches minimum and 4.265 inches maximum
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Features Provided
nut and washer
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference