AP1-4-4-2-102

Circuit Breakers

CIRCUIT BREAKER

AP1-4-4-2-102

5925-00-189-4312

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    80063-sm-a-569574 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug and 2 wire hook

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Special Handling Feature

    magnetic

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    explosion resistant and hermetically sealed

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct single location and 4.000 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...