CIRCUIT BREAKER

SM6-0-75-250-400-1

5925-00-189-4318

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes ac single location

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 4.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    explosion resistant and hermetically sealed

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...