AP1-3-4-2-302

Circuit Breakers

CIRCUIT BREAKER

AP1-3-4-2-302

5925-00-189-4319

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Unpackaged Unit Weight

    2.100 ounces

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Ultimate Trip Time Per Pole In Seconds

    6.500 minimum all locations and 30.000 maximum all locations

  • Body Width

    0.598 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 4.000 maximum at 200 pct all locations

  • Thread Series Designator

    unef

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Bushing Length

    0.375 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.555 inches nominal

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and hermetically sealed

  • Thread Quantity Per Inch

    32

  • Body Length

    1.479 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...