M5757-51-004
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M5757-51-004
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Nominal Operating Current Rating And Type
50.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes dc resistive load
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Duty Type
continuous
-
Mounting Facility Pattern
rectangular single mounting facility
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Main Contact Maximum Voltage Rating In Volts
26.5 dc
-
Environmental Protection
hermetic
-
Time Delay
1.00 seconds minimum adjustable operate time and 15.00 seconds maximum adjustable operate time
-
Winding Quantity
1
-
Unthreaded Mounting Hole Diameter
0.120 inches nominal single mounting facility
-
Operating Voltage Rating And Type At Specified Temp
20.0 volts teardrop, two holes type 4f single winding
-
Overall Width
1.350 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches nominal single mounting facility
-
Overall Height
0.400 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.197 inches nominal single mounting facility
-
Overall Length
1.537 inches maximum