3XAM1516MG3-50-120-2-400

Circuit Breakers

CIRCUIT BREAKER

3XAM1516MG3-50-120-2-400

5925-00-190-0095

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Length

    3.719 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.500 minimum at 200 pct all locations and 0.700 minimum at 400 pct all locations and 10.700 maximum at 200 pct all locations and 1.100 maximum at 400 pct all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    11.000 minimum all locations and 70.000 maximum all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.156 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Style

    multipole-single actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Width

    3.052 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

  • Mounting Surface To Terminal End Distance

    3.359 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...