13981
Coils and Transformers
TRANSFORMER,POWER
13981
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Body Length
3.125 inches maximum
-
Body Height
2.625 inches maximum
-
Maximum Operating Temp
130.0 deg celsius
-
Mounting Method
unthreaded hole
-
Winding Tap Location
multiple taps w/o center tap
-
Winding Operating Current
1.5 amperes dc nominal
-
Winding Operating Current
50.0 milliamperes dc nominal
-
Winding Power Rating
1.5 volts-amperes
-
Winding Power Rating
12.8 volts-amperes
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.875 inches nominal
-
Frequency Rating
50.0 hertz minimum and 420.0 hertz maximum
-
Body Width
2.500 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
1 primary and 2 secondary
-
Winding Tap Location
center tap
-
Winding Operating Voltage
30.00 dc volts nominal
-
Winding Operating Voltage
8.50 dc volts nominal
-
Winding Operating Voltage
90.00 ac volts nominal and 100.00 ac volts nominal and 110.00 ac volts nominal
-
Terminal Type And Quantity
10 tab,solder lug