109-215-101

Circuit Breakers

CIRCUIT BREAKER

109-215-101

5925-00-191-9757

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Time Per Pole In Seconds

    40.000 minimum single location and 200.000 maximum single location

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 ac single location and 5000.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Bushing Length

    0.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Thread Quantity Per Inch

    24

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 maximum at 200 pct single location and 2.500 minimum at 300 pct single location and 9.000 minimum at 200 pct single location and 5.500 maximum at 300 pct single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Series Designator

    unf

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.375 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Mounting Surface To Terminal End Distance

    2.035 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Width

    0.687 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 32.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.020 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...