EH3010M0DIFIED

Circuit Breakers

CIRCUIT BREAKER

EH3010M0DIFIED

5925-00-195-6257

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    4.110 inches minimum and 4.130 inches maximum

  • Body Height

    3.180 inches minimum and 3.200 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.740 inches minimum and 2.760 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.960 inches minimum and 2.160 inches maximum

  • Boss Height

    0.300 inches minimum and 0.320 inches maximum

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Location And Position Designation

    internal at pole one and internal at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct and 80.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum

  • Switch Terminal Type

    wire lead

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Length

    6.490 inches minimum and 6.510 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.678 inches minimum and 0.698 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.928 inches minimum and 4.948 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac

  • Trip Release Method

    thermal-magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Inclosure Protection Type For Which Designed

    vibration resistant and moisture resistant and shock resistant and fungus resistant and corrosion resistant

  • Switch Voltage Rating And Type In Volts

    240.0 ac

  • Frequency In Hertz

    400.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...