4MC17-1-50

Circuit Breakers

CIRCUIT BREAKER

4MC17-1-50

5925-00-196-3733

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.500 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc single location

  • Boss Height

    0.125 inches nominal

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.680 inches nominal

  • Trip Release Characteristic

    instantaneous single location

  • Operating Voltage Type And Rating Per Pole In Volts

    60.0 dc single location

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.810 inches nominal

  • Trip Release Method

    magnetic single location

  • Switch Terminal Type

    tab, solder lug

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Reset Method

    manual

  • Body Length

    2.300 inches maximum

  • Actuator Position Designation

    at pole one

  • Ultimate Trip Time Per Pole In Seconds

    0.020 nominal single location

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...