12MC14-204-15
Circuit Breakers
CIRCUIT BREAKER
12MC14-204-15
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Precious Material
silver and gold
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.720 inches minimum and 0.760 inches maximum
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Switch Current Rating And Type In Amps
5.0 ac
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
1.845 inches minimum and 1.905 inches maximum
-
Body Length
2.300 inches maximum
-
Boss Height
0.115 inches minimum and 0.135 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.016 minimum at 200 pct all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Length
1.670 inches minimum and 1.690 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Inclosure Protection Type For Which Designed
vibration resistant
-
Switch Location And Position Designation
internal between pole one and two
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.720 inches minimum and 0.760 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Manual Actuator Type And Quantity
2 toggle
-
Body Width
1.500 inches minimum and 1.560 inches maximum
-
Precious Material And Location
internal contacts silver and auxiliary terminals gold
-
Frequency In Hertz
400.0 all locations
-
Unpackaged Unit Weight
8.000 ounces
-
Switch Terminal Type
pin
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Terminal Type And Quantity
4 threaded stud
-
External Actuator Linkage Arrangement
one and two linked
-
Switch Voltage Rating And Type In Volts
125.0 ac
-
Case Material
plastic