D9204
Coils and Transformers
TRANSFORMER,POWER
D9204
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
900.0 milliamperes ac maximum single component 2nd secondary
-
Body Width
3.125 inches nominal
-
Thread Class (Non-Core)
err-070
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility single center group
-
Winding Operating Voltage
5.00 ac volts nominal single component 1st secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Terminal Type And Quantity
14 tab, solder lug
-
Unpackaged Unit Weight (Non-Core)
4.000 pounds
-
Winding Operating Current
2.0 amperes ac maximum single component 1st secondary
-
Inclosure Type
hermetically sealed
-
Reliability Indicator
not established
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Maximum Operating Temp
105.0 deg celsius
-
Thread Series Designator
unf single group
-
Body Height
4.000 inches maximum
-
Thread Quantity Per Inch
32 single group
-
Mounting Method
threaded stud single group
-
Winding Tap Location (Non-Core)
err-070
-
Body Length
3.375 inches nominal
-
Overall Length
3.375 inches nominal
-
Winding Operating Current
1.8 amperes ac maximum single component 3rd secondary
-
Overall Width
3.125 inches nominal
-
Winding Operating Current
50.0 milliamperes ac maximum single component 4th secondary
-
Winding Function And Quantity
2 primary single component and 4 secondary single component
-
Winding Operating Voltage
750.00 ac volts nominal single component 4th secondary
-
Mounting Facility Quantity
4 single group
-
Frequency Rating
50.0 hertz minimum single component and 70.0 hertz maximum single component
-
Winding Operating Voltage
115.00 ac volts nominal single component all primary
-
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
-
Overall Height
4.812 inches maximum
-
Nominal Thread Size
0.190 inches single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group