AM1516MG3-90-32VDC1

Circuit Breakers

CIRCUIT BREAKER

AM1516MG3-90-32VDC1

5925-00-201-2184

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Thread Series Designator

    unc

  • Body Length

    3.719 inches nominal

  • Body Width

    0.990 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.156 inches nominal

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Pole Quantity

    1

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Body Style

    12a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...