DMS 83041B

Circuit Breakers

CIRCUIT BREAKER

DMS 83041B

5925-00-201-2244

5925 - Circuit Breakers

Defense Electronics Supply Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Body Width

    1.030 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    1 compression and 1 tab w/screw

  • Body Length

    4.750 inches nominal

  • Switch Terminal Type

    pin

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Height

    2.830 inches nominal

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Unpackaged Unit Weight

    0.688 pounds

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    4.380 inches nominal

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...