DMS 83041B

Circuit Breakers

CIRCUIT BREAKER

DMS 83041B

5925-00-201-2244

5925 - Circuit Breakers

Dla Land And Maritime

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Body Width

    1.030 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    1 compression and 1 tab w/screw

  • Body Length

    4.750 inches nominal

  • Switch Terminal Type

    pin

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Height

    2.830 inches nominal

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Unpackaged Unit Weight

    0.688 pounds

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    4.380 inches nominal

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.