AN3161-5
Circuit Breakers
CIRCUIT BREAKER
AN3161-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
2.188 inches nominal
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Overall Width
0.750 inches nominal
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Overall Height
2.625 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Reset Method
automatic
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location