6752-302-2 1/2

Circuit Breakers

CIRCUIT BREAKER

6752-302-2 1/2

5925-00-202-9133

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 tab w/screw

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    0.700 pounds

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Terminal Type

    wire lead

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Location And Position Designation

    internal at pole three

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push-pull

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac and 50.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac and 2.5 amperes dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.720 inches minimum and 0.780 inches maximum

  • Case Material

    plastic

  • Body Height

    2.440 inches minimum and 2.500 inches maximum

  • Body Length

    2.189 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 34.000 maximum at 200 pct

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole two

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    thermal-magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac and 4200.0 dc

  • Special Handling Feature

    magnetic

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.470 inches minimum and 1.530 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.720 inches minimum and 0.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Body Width

    2.250 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...