2263AMG3-50-125VAC60-2
Circuit Breakers
CIRCUIT BREAKER
2263AMG3-50-125VAC60-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Height
2.697 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
4.349 inches minimum and
-
Center To Center Distance Between Terminals Parallel To Width
0.974 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.052 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.990 inches minimum and
-
Boss Height
0.208 inches minimum and
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Mounting Facility Type And Quantity
4 threaded hole and
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Body Width
1.990 inches minimum and
-
Body Height
2.677 inches minimum and
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
4.369 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.994 inches maximum
-
Unthreaded Mounting Hole Diameter
0.190 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.072 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.010 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Boss Height
0.228 inches maximum
-
Pole Quantity
2
-
Iii Arc Quenching Method
magnetic blowout
-
Iii Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Actuator Position Designation
between pole one and two
-
Internal Trip Release Configuration
series trip all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
5.500 minimum at 200 pct and
-
Inclosure Protection Type For Which Designed
fungus proof
-
Thread Series Designator
unc
-
Body Style
9b multipole-single actuator type
-
Body Length
5.240 inches minimum and
-
Body Length
5.260 inches maximum
-
Body Width
2.010 inches maximum
-
Nominal Thread Size
0.164 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct all locations
-
Inclosure Protection Type For Which Designed
dustproof and
-
Frequency In Hertz
60.0 all locations
-
Terminal Type And Quantity
4 threaded stud