JLD4A
Relays and Solenoids
RELAY,ELECTROMAGNETIC
JLD4A
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
10 pin all functions
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Width
1.300 inches nominal
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Overall Length
1.718 inches maximum
-
Winding Quantity
2
-
Time Delay
0.01 seconds maximum fixed operate time
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.420 inches nominal single mounting facility
-
Winding Dc Resistance Rating
600.0 ohms nominal all windings
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Coil Quantity
2
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f all windings
-
Overall Height
0.515 inches nominal
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Features Provided
polarized and latching contacts
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load