458D509G12W/AUX

Circuit Breakers

CIRCUIT BREAKER

458D509G12W/AUX

5925-00-216-4042

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    5.562 inches nominal

  • Case Material

    plastic

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Switch Voltage Rating And Type In Volts

    450.0 ac and 120.0 dc

  • Switch Terminal Type

    clip

  • Body Width

    4.125 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Length

    6.500 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Boss Height

    0.187 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    50.0 deg celsius maximum all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.625 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Reset Method

    manual

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Terminal Type And Quantity

    6 clip

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Height

    3.875 inches nominal

  • Switch Location And Position Designation

    internal at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...