A2542
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
A2542
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Average Life Rating In Hours
250.0
-
Input Impedance Per Function W/Load
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
40.0 2nd radio interference
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 2nd radio interference
-
Overall Height
3.550 inches nominal
-
Operating Current Rating Per Function In Amps
40.0 3rd radio interference
-
Functional Terminal Type And Quantity
2 solder stud ground 3rd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Input Impedance Per Function W/Load
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 1st radio interference 1st function
-
Body Height
2.750 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Functional Terminal Type And Quantity
1 threaded stud input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 2nd radio interference 2nd function
-
Body Width
11.500 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
100.0 millivolts ac 1st radio interference
-
Body Length
12.062 inches nominal
-
Unthreaded Mounting Hole Diameter
0.250 inches nominal
-
Maximum Dielectric Withstanding Dc Voltage
1.9 kilovolts at sea level
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
100.0 millivolts ac 2nd radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 3rd radio interference 3rd function
-
Overall Length
12.937 inches nominal
-
Maximum Voltage Drop Per Function
100.0 millivolts ac 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Functional Terminal Type And Quantity
1 threaded stud output 2nd function
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 1st radio interference
-
Operating Temp Range
-65.0/+85.0 deg celsius
-
Input Impedance Per Function W/Load
50.0 ohms 1st radio interference
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Current Rating Per Function In Amps
40.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Input Terminal Manufacturer Code
96906
-
Input Terminal Identification
ms3102r36-5p