Technical Characteristics

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.665 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Nominal Thread Size

    0.125 inches

  • Actuator Position Designation

    between pole two and three

  • Internal Trip Release Configuration

    relay trip all locations

  • Mounting Surface To Terminal End Distance

    2.658 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Body Width

    1.530 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free and nontrip free

  • Boss Height

    0.140 inches nominal

  • Body Length

    2.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Terminal Type And Quantity

    7 threaded stud

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.952 inches maximum

  • Case Material

    metal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Facility Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unf

  • Reset Method

    manual

  • Actuator Function

    trip w/separate reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...