18-084
Coils and Transformers
TRANSFORMER,POWER
18-084
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
212.00 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
117.00 ac volts nominal single component single primary
-
Mounting Facility Quantity
4 single group
-
Body Outside Diameter
1.750 inches nominal
-
Frequency Rating
50.0 hertz minimum and 60.0 hertz maximum single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.812 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
7 tab, solder lug
-
Special Features
case metal material
-
Winding Operating Voltage
5.70 ac volts nominal single component 1st secondary
-
Winding Operating Current
4.0 milliamperes dc maximum single component 2nd secondary
-
Winding Operating Current
1.7 amperes dc maximum single component 1st secondary
-
(Non-Core Data) Winding Tap Location
center tap single component 2nd secondary
-
Winding Function And Quantity
1 primary and 2 secondary single component
-
Mounting Method
flange and unthreaded hole single group
-
Inclosure Type
open
-
Body Length
2.875 inches nominal
-
Input-Output Phase Relationship
single phase to single phase single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.812 inches nominal single mounting facility single center group
-
Reliability Indicator
not established