Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
-
Bushing Length
0.516 inches minimum and 0.546 inches maximum
-
Nominal Thread Size
0.438 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 minimum at 200 pct single location and 45.000 maximum at 200 pct single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Manual Actuator Type And Quantity
1 push button
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Center To Center Distance Between Terminals Parallel To Length
0.834 inches minimum and 0.854 inches maximum
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.646 inches minimum and 1.666 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Inclosure Protection Type For Which Designed
general purpose
-
Terminal Type And Quantity
2 quick disconnect, male
-
Body Style
single pole type
-
Body Length
1.365 inches minimum and 1.385 inches maximum
-
Body Width
0.552 inches minimum and 0.572 inches maximum
-
Frequency In Hertz
60.0 single location
-
Thread Series Designator
unef
-
Thread Quantity Per Inch
28
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Actuator Function
reset
-
Fragility Factor
moderately rugged