9011-000-1000
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
9011-000-1000
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Range
-55.0/+85.0 deg fahrenheit
-
Functional Terminal Type And Quantity
1 tab, solder lug input 1st function
-
Functional Terminal Type And Quantity
1 tab, solder lug output 2nd function
-
Power Line Frequency Rating Per Function In Hertz
400.0 blank
-
Test Data Document
10236-7140007 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Operating Current Rating Per Function In Amps
1.0 blank
-
Body Outside Diameter
0.687 inches nominal
-
Nominal Thread Size
0.625 inches
-
Mounting Facility Screw Thread Series Designator
unef
-
Operating Voltage Rating And Type Per Function
115.0 volts ac blank and 250.0 volts dc blank
-
Inclosure Type
hermetically sealed
-
Style Designator
round terminal/terminals on opposite surfaces
-
Overall Length
1.655 inches minimum and 1.745 inches maximum