72-287-2-MG6

Circuit Breakers

CIRCUIT BREAKER

72-287-2-MG6

5925-00-224-6193

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Auxiliary Switch Function And Quantity

    1 control

  • Body Style

    multipole-multiple actuator type

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct all locations and 8.500 maximum at 200 pct all locations

  • Switch Location And Position Designation

    internal between pole one and two

  • Maximum Continuous Load Current Rating Per Pole

    54.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.