9254
Relays and Solenoids
RELAY,ELECTROMAGNETIC
9254
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac inductive load and 10.0 amperes dc inductive load
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.125 inches nominal first mounting facility
-
Mounting Facility Type And Quantity
4 unthreaded hole second mounting facility
-
Mounting Facility Pattern
rectangular second mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.125 inches nominal second mounting facility
-
Unthreaded Mounting Hole Diameter
0.173 inches nominal first mounting facility
-
Storage Type
general purpose warehouse
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Width
1.625 inches maximum
-
Unthreaded Mounting Hole Diameter
0.173 inches nominal second mounting facility
-
Specification/Standard Data
96906-ms24149 government standard
-
Environmental Protection
hermetic
-
Arc Quenching Method
air
-
Winding Dc Resistance Rating
160.0 ohms nominal single winding
-
Winding Quantity
1
-
Overall Length
2.500 inches maximum
-
~1
data on certain environmental and performance
-
Overall Height
2.600 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal first mounting facility
-
Case Material
metal
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Time Delay
0.01 seconds maximum fixed release time
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal second mounting facility
-
Cubic Measure
10.562 cubic inches
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Nominal Operating Current Rating And Type
250.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes ac motor load and 6.0 amperes dc motor load
-
Mounting Facility Type And Quantity
4 unthreaded hole first mounting facility
-
Mounting Facility Pattern
rectangular first mounting facility
-
Terminal Type And Quantity
8 screw all functions
-
Time Delay
0.025 seconds maximum fixed operate time
-
Duty Type
continuous
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load