A5045
Coils and Transformers
TRANSFORMER,POWER
A5045
Autodyne Manufacturing Co. Inc.
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
2.30 dc kilovolts nominal single component 1st secondary
-
Winding Operating Current
2.5 amperes dc maximum single component 3rd secondary
-
Winding Operating Voltage
50.00 dc volts nominal single component 3rd secondary
-
Winding Operating Voltage
27.00 dc volts nominal single component single primary
-
Maximum Operating Temp
110.0 deg celsius
-
Winding Operating Current
350.0 milliamperes dc maximum single component 1st secondary
-
Inclosure Type
fully inclosed
-
Frequency Rating
1.2 kilohertz nominal single component
-
Winding Shielding Method
internal shield grounded to inclosure and brought out to terminal single component
-
Terminal Type And Quantity
5 turret and 2 wire lead and 3 wire hook
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Mounting Method
bracket single group
-
Winding Operating Voltage
500.00 dc volts nominal single component 2nd secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Current
150.0 milliamperes dc maximum single component 2nd secondary