3MC1-3-3
Circuit Breakers
CIRCUIT BREAKER
3MC1-3-3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
magnetic single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location
-
Terminal Type And Quantity
2 screw
-
Thread Quantity Per Inch
32
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 0.800 maximum at 200 pct single location
-
Circuit Protection Type
overcurrent single location
-
Bushing Length
0.548 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Body Width
0.656 inches nominal
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 2500.0 dc single location
-
Frequency In Hertz
400.0 single location
-
Inclosure Protection Type For Which Designed
general purpose
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
1.688 inches nominal
-
Mounting Surface To Terminal End Distance
1.669 inches nominal
-
Nominal Thread Size
0.469 inches
-
Body Length
1.781 inches nominal
-
Thread Series Designator
uns
-
Case Material
plastic