2595D1036-2

Circuit Breakers

CIRCUIT BREAKER

2595D1036-2

5925-00-229-1479

5925 - Circuit Breakers

Bae Systems Information And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.332 inches minimum and

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Inclosure Protection Type For Which Designed

    sandtight and

  • Inclosure Protection Type For Which Designed

    shockproof and

  • Iii Unpackaged Unit Weight

    1.800 ounces

  • Test Data Document

    87557-2595d1036 drawing

  • Terminal Type And Quantity

    2 wire hook

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.375 inches maximum

  • Body Length

    1.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.25 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and

  • Inclosure Protection Type For Which Designed

    humidity proof and

  • Inclosure Protection Type For Which Designed

    salt spray proof and

  • Inclosure Protection Type For Which Designed

    vibrationproof and

  • Thread Series Designator

    unef

  • Specification/Standard Data

    87557-2595d1036 manufacturers source control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...