536001-3

Circuit Breakers

CIRCUIT BREAKER

536001-3

5925-00-229-7551

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Bushing Length

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    0.125 pounds

  • Nominal Thread Size

    0.469 inches

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.020 minimum at 200 pct single location and 0.090 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Inclosure Protection Type For Which Designed

    explosion proof and fungus proof

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 28.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Body Width

    0.656 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location

  • Frequency In Hertz

    400.0 single location

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Mounting Surface To Terminal End Distance

    1.669 inches maximum

  • Body Style

    single pole type

  • Body Length

    1.781 inches maximum

  • Switch Terminal Type

    pin

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.