6614A4
Switches
SWITCH,PRESSURE
6614A4
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
10.0 amperes resistive load single voltage and 3.0 amperes inductive load single voltage
-
Style Designator
cylindrical
-
Err Default
err default
-
Terminal Type
connector, receptacle
-
Body Length
2.060 inches nominal
-
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Proof Pressure
115.00 pounds per square inch gage
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 270.0 deg fahrenheit maximum
-
Distance Between Mounting Facility Centers
1.250 inches nominal
-
Thread Class
2a all threaded stud
-
Media For Which Designed
gas
-
Overall Diameter
1.810 inches nominal
-
Thread Series Designator
unf all threaded stud
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Pressure Connector Type
flared, threaded external single connection
-
Nominal Thread Size
0.190 inches all threaded stud
-
Pressure Switch Type
gage
-
Mounting Method
base and threaded stud
-
Mounting Facility Pattern
two position in-line
-
Outside Diameter
0.469 inches nominal single connection
-
Overall Length
3.250 inches nominal
-
Contact Stimulus Rating
10.00 actuation point nominal pounds per square inch gage and 5.00 deactuation point nominal pounds per square inch gage
-
Contact Action Stimulus
increase