2892361-4

Circuit Breakers

CIRCUIT BREAKER

2892361-4

5925-00-231-3660

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    300.0 ac single location and 125.0 dc single location

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Switch Terminal Type

    turret

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    dustproof

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Boss Height

    0.178 inches minimum and 0.198 inches maximum

  • Body Height

    3.040 inches minimum and 3.080 inches maximum

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Mounting Facility Type And Quantity

    2 terminal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    1 solder stud and 1 tab w/screw

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    thermal-magnetic single location

  • Switch Location And Position Designation

    external at pole one

  • Body Width

    0.940 inches minimum and 0.980 inches maximum

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    3.480 inches minimum and 3.520 inches maximum

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 210.000 maximum at 200 pct single location

  • Arc Quenching Method

    air

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...