W503A
Coils and Transformers
TRANSFORMER,POWER
W503A
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Shielding Method
internal shield brought out to terminal
-
Body Height
3.940 inches maximum
-
Mounting Slot Width
0.203 inches nominal
-
Winding Shielding Method
core grounded
-
Winding Function And Quantity
1 primary and 2 secondary
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.875 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.938 inches nominal
-
Frequency Rating
400.0 hertz nominal
-
Input-Output Phase Relationship
three phase to three phase
-
Body Length
4.630 inches maximum
-
Body Width
2.500 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Mounting Method
flange and slot
-
Winding Operating Current
1.5 amperes ac maximum
-
Winding Operating Current
16.4 amperes ac maximum
-
Winding Operating Voltage
208.00 ac volts nominal
-
Winding Operating Voltage
31.50 ac volts nominal
-
Winding Operating Voltage
5.60 ac volts nominal
-
Terminal Type And Quantity
12 turret