711525-35

Circuit Breakers

CIRCUIT BREAKER

711525-35

5925-00-233-5125

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac all locations and 4200.0 dc all locations

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    18.000 minimum at 200 pct all locations and 47.000 maximum at 200 pct all locations

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    2.250 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations and 15.0 amperes dc all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Center To Center Distance Between Terminals Parallel To Length

    1.180 inches minimum and 1.200 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac all locations and 50.0 dc all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal-magnetic all locations

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Unpackaged Unit Weight

    2.100 pounds

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    turret

  • Switch Location And Position Designation

    internal at pole three

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Body Width

    2.189 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Body Height

    2.460 inches minimum and 2.480 inches maximum

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...